Stokes parameters

1

The Stokes parameters are a set of values that describe the polarization state of electromagnetic radiation. They were defined by George Gabriel Stokes in 1852, as a mathematically convenient alternative to the more common description of incoherent or partially polarized radiation in terms of its total intensity (I), (fractional) degree of polarization (p), and the shape parameters of the polarization ellipse. The effect of an optical system on the polarization of light can be determined by constructing the Stokes vector for the input light and applying Mueller calculus, to obtain the Stokes vector of the light leaving the system. They can be determined from directly observable phenomena. The original Stokes paper was discovered independently by Francis Perrin in 1942 and by Subrahamanyan Chandrasekhar in 1947, who named it as the Stokes parameters.

Definitions

The relationship of the Stokes parameters S0, S1, S2, S3 to intensity and polarization ellipse parameters is shown in the equations below and the figure on the right. Here I p, 2\psi and 2\chi are the spherical coordinates of the three-dimensional vector of cartesian coordinates. I is the total intensity of the beam, and p is the degree of polarization, constrained by. The factor of two before \psi represents the fact that any polarization ellipse is indistinguishable from one rotated by 180°, while the factor of two before \chi indicates that an ellipse is indistinguishable from one with the semi-axis lengths swapped accompanied by a 90° rotation. The phase information of the polarized light is not recorded in the Stokes parameters. The four Stokes parameters are sometimes denoted I, Q, U and V, respectively. Given the Stokes parameters, one can solve for the spherical coordinates with the following equations:

Stokes vectors

The Stokes parameters are often combined into a vector, known as the Stokes vector: The Stokes vector spans the space of unpolarized, partially polarized, and fully polarized light. For comparison, the Jones vector only spans the space of fully polarized light, but is more useful for problems involving coherent light. The four Stokes parameters are not a preferred coordinate system of the space, but rather were chosen because they can be easily measured or calculated. Note that there is an ambiguous sign for the V component depending on the physical convention used. In practice, there are two separate conventions used, either defining the Stokes parameters when looking down the beam towards the source (opposite the direction of light propagation) or looking down the beam away from the source (coincident with the direction of light propagation). These two conventions result in different signs for V, and a convention must be chosen and adhered to.

Examples

Below are shown some Stokes vectors for common states of polarization of light. |- | || Linearly polarized (horizontal) |- | || Linearly polarized (vertical) |- | || Linearly polarized (+45°) |- | || Linearly polarized (−45°) |- | || Right-hand circularly polarized |- | || Left-hand circularly polarized |- | || Unpolarized

Alternative explanation

A monochromatic plane wave is specified by its propagation vector, \vec{k}, and the complex amplitudes of the electric field, E_1 and E_2, in a basis. The pair (E_1, E_2) is called a Jones vector. Alternatively, one may specify the propagation vector, the phase, \phi, and the polarization state, \Psi, where \Psi is the curve traced out by the electric field as a function of time in a fixed plane. The most familiar polarization states are linear and circular, which are degenerate cases of the most general state, an ellipse. One way to describe polarization is by giving the semi-major and semi-minor axes of the polarization ellipse, its orientation, and the direction of rotation (See the above figure). The Stokes parameters I, Q, U, and V, provide an alternative description of the polarization state which is experimentally convenient because each parameter corresponds to a sum or difference of measurable intensities. The next figure shows examples of the Stokes parameters in degenerate states.

Definitions

The Stokes parameters are defined by where the subscripts refer to three different bases of the space of Jones vectors: the standard Cartesian basis, a Cartesian basis rotated by 45° , and a circular basis. The circular basis is defined so that,. The symbols ⟨⋅⟩ represent expectation values. The light can be viewed as a random variable taking values in the space C2 of Jones vectors (E_1, E_2). Any given measurement yields a specific wave (with a specific phase, polarization ellipse, and magnitude), but it keeps flickering and wobbling between different outcomes. The expectation values are various averages of these outcomes. Intense, but unpolarized light will have I > 0 but Q = U = V = 0, reflecting that no polarization type predominates. A convincing waveform is depicted at the article on coherence. The opposite would be perfectly polarized light which, in addition, has a fixed, nonvarying amplitude—a pure sine curve. This is represented by a random variable with only a single possible value, say (E_1, E_2). In this case one may replace the brackets by absolute value bars, obtaining a well-defined quadratic map from the Jones vectors to the corresponding Stokes vectors; more convenient forms are given below. The map takes its image in the cone defined by |I |2 = |Q |2 + |U |2 + |V |2, where the purity of the state satisfies p = 1 (see below). The next figure shows how the signs of the Stokes parameters are determined by the helicity and the orientation of the semi-major axis of the polarization ellipse.

Representations in fixed bases

In a fixed basis, the Stokes parameters when using an increasing phase convention are while for, they are and for, they are

Properties

For purely monochromatic coherent radiation, it follows from the above equations that whereas for the whole (non-coherent) beam radiation, the Stokes parameters are defined as averaged quantities, and the previous equation becomes an inequality: However, we can define a total polarization intensity I_p, so that where I_p/I is the total polarization fraction. Let us define the complex intensity of linear polarization to be Under a rotation of the polarization ellipse, it can be shown that I and V are invariant, but With these properties, the Stokes parameters may be thought of as constituting three generalized intensities: where I is the total intensity, |V| is the intensity of circular polarization, and |L| is the intensity of linear polarization. The total intensity of polarization is, and the orientation and sense of rotation are given by Since and, we have

Relation to the polarization ellipse

In terms of the parameters of the polarization ellipse, the Stokes parameters are Inverting the previous equation gives

Measurement

The Stokes parameters (and thus the polarization of some electromagnetic radiation) can be directly determined from observation. Using a linear polarizer and a quarter-wave plate, the following system of equations relating the Stokes parameters to measured intensity can be obtained: where I_l(\theta) is the irradiance of the radiation at a point when the linear polarizer is rotated at an angle of \theta, and similarly I_q(\theta) is the irradiance at a point when the quarter-wave plate is rotated at an angle of \theta. A system can be implemented using both plates at once at different angles to measure the parameters. This can give a more accurate measure of the relative magnitudes of the parameters (which is often the main result desired) due to all parameters being affected by the same losses.

Relationship to Hermitian operators and quantum mixed states

From a geometric and algebraic point of view, the Stokes parameters stand in one-to-one correspondence with the closed, convex, 4-real-dimensional cone of nonnegative Hermitian operators on the Hilbert space C2. The parameter I serves as the trace of the operator, whereas the entries of the matrix of the operator are simple linear functions of the four parameters I, Q, U, V, serving as coefficients in a linear combination of the Stokes operators. The eigenvalues and eigenvectors of the operator can be calculated from the polarization ellipse parameters I, p, ψ, χ. The Stokes parameters with I set equal to 1 (i.e. the trace 1 operators) are in one-to-one correspondence with the closed unit 3-dimensional ball of mixed states (or density operators) of the quantum space C2, whose boundary is the Bloch sphere. The Jones vectors correspond to the underlying space C2, that is, the (unnormalized) pure states of the same system. Note that the overall phase (i.e. the common phase factor between the two component waves on the two perpendicular polarization axes) is lost when passing from a pure state |φ⟩ to the corresponding mixed state |φ⟩⟨φ|, just as it is lost when passing from a Jones vector to the corresponding Stokes vector. In the basis of horizontal polarization state |H\rangle and vertical polarization state |V\rangle, the +45° linear polarization state is, the -45° linear polarization state is , the left hand circular polarization state is , and the right hand circular polarization state is. It's easy to see that these states are the eigenvectors of Pauli matrices, and that the normalized Stokes parameters (U/I, V/I, Q/I) correspond to the coordinates of the Bloch vector (a_x, a_y, a_z). Equivalently, we have, , , where \rho is the density matrix of the mixed state. Generally, a linear polarization at angle θ has a pure quantum state ; therefore, the transmittance of a linear polarizer/analyzer at angle θ for a mixed state light source with density matrix is, with a maximum transmittance of at if a_z > 0, or at if a_z < 0; the minimum transmittance of is reached at the perpendicular to the maximum transmittance direction. Here, the ratio of maximum transmittance to minimum transmittance is defined as the extinction ratio, where the degree of linear polarization is. Equivalently, the formula for the transmittance can be rewritten as, which is an extended form of Malus's law; here, A, B are both non-negative, and is related to the extinction ratio by. Two of the normalized Stokes parameters can also be calculated by. It's also worth noting that a rotation of polarization axis by angle θ corresponds to the Bloch sphere rotation operator. For example, the horizontal polarization state |H\rangle would rotate to. The effect of a quarter-wave plate aligned to the horizontal axis is described by, or equivalently the Phase gate S, and the resulting Bloch vector becomes. With this configuration, if we perform the rotating analyzer method to measure the extinction ratio, we will be able to calculate a_y and also verify a_z. For this method to work, the fast axis and the slow axis of the waveplate must be aligned with the reference directions for the basis states. The effect of a quarter-wave plate rotated by angle θ can be determined by Rodrigues' rotation formula as, with. The transmittance of the resulting light through a linear polarizer (analyzer plate) along the horizontal axis can be calculated using the same Rodrigues' rotation formula and focusing on its components on I and \sigma_z: The above expression is the theory basis of many polarimeters. For unpolarized light, T=1/2 is a constant. For purely circularly polarized light, T has a sinusoidal dependence on angle θ with a period of 180 degrees, and can reach absolute extinction where T=0. For purely linearly polarized light, T has a sinusoidal dependence on angle θ with a period of 90 degrees, and absolute extinction is only reachable when the original light's polarization is at 90 degrees from the polarizer (i.e. a_z =-1). In this configuration, and, with a maximum of 1/2 at θ=45°, and an extinction point at θ=0°. This result can be used to precisely determine the fast or slow axis of a quarter-wave plate, for example, by using a polarizing beam splitter to obtain a linearly polarized light aligned to the analyzer plate and rotating the quarter-wave plate in between. Similarly, the effect of a half-wave plate rotated by angle θ is described by, which transforms the density matrix to: The above expression demonstrates that if the original light is of pure linear polarization (i.e. a_y= 0), the resulting light after the half-wave plate is still of pure linear polariztion (i.e. without \sigma_y component) with a rotated major axis. Such rotation of the linear polarization has a sinusoidal dependence on angle θ with a period of 90 degrees.

This article is derived from Wikipedia and licensed under CC BY-SA 4.0. View the original article.

Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.
Bliptext is not affiliated with or endorsed by Wikipedia or the Wikimedia Foundation.

View original