Ethernet physical layer

1

The physical-layer specifications of the Ethernet family of computer network standards are published by the Institute of Electrical and Electronics Engineers (IEEE), which defines the electrical or optical properties and the transfer speed of the physical connection between a device and the network or between network devices. It is complemented by the MAC layer and the logical link layer. An implementation of a specific physical layer is commonly referred to as PHY. The Ethernet physical layer has evolved over its existence starting in 1980 and encompasses multiple physical media interfaces and several orders of magnitude of speed from 1 Mbit/s to 400 Gbit/s. The physical medium ranges from bulky coaxial cable to twisted pair and optical fiber with a standardized reach of up to 80 km. In general, network protocol stack software will work similarly on all physical layers. Many Ethernet adapters and switch ports support multiple speeds by using autonegotiation to set the speed and duplex for the best values supported by both connected devices. If autonegotiation fails, some multiple-speed devices sense the speed used by their partner, but this may result in a duplex mismatch. With rare exceptions, a 100BASE-TX port (10/100) also supports 10BASE-T while a 1000BASE-T port (10/100/1000) also supports 10BASE-T and 100BASE-TX. Most 10GBASE-T ports also support 1000BASE-T, some even 100BASE-TX or 10BASE-T. While autonegotiation can practically be relied on for Ethernet over twisted pair, few optical-fiber ports support multiple speeds. In any case, even multi-rate fiber interfaces only support a single wavelength (e.g. 850 nm for 1000BASE-SX or 10GBASE-SR). 10 Gigabit Ethernet was already used in both enterprise and carrier networks by 2007, with 40 Gbit/s and 100 Gigabit Ethernet ratified. In 2017, the fastest additions to the Ethernet family were 200 and 400 Gbit/s. Development of 800 Gbit/s and 1.6 Tbit/s Ethernet standards started in 2021.

Naming conventions

Generally, layers are named by their specifications: For 10 Mbit/s, no encoding is indicated as all variants use Manchester code. Most twisted pair layers use unique encoding, so most often just -T is used. The reach, especially for optical connections, is defined as the maximum achievable link length that is guaranteed to work when all channel parameters are met (modal bandwidth, attenuation, insertion losses etc.). With better channel parameters, often a longer, stable link length can be achieved. Vice versa, a link with worse channel parameters can also work but only over a shorter distance. Reach and maximum distance have the same meaning.

Physical layers

The following sections provide a brief summary of official Ethernet media types. In addition to these official standards, many vendors have implemented proprietary media types for various reasons—often to support longer distances over fiber optic cabling.

Early implementations and 10 Mbit/s

Early Ethernet standards used Manchester coding so that the signal was self-clocking and not adversely affected by high-pass filters.

100 Mbit/s

All Fast Ethernet variants use a star topology and generally use 4B5B line coding.

1 Gbit/s

All Gigabit Ethernet variants use a star topology. 1000BASE-X variants use 8b/10b PCS encoding. Initially, half-duplex mode was included in the standard but has since been abandoned. Very few devices support gigabit speed in half-duplex.

2.5 and 5 Gbit/s

2.5GBASE-T and 5GBASE-T are scaled-down variants of 10GBASE-T and provide longer reach over pre-Cat 6A cabling. These physical layers support twisted-pair copper cabling and backplanes only.

10 Gbit/s

10 Gigabit Ethernet is a version of Ethernet with a nominal data rate of 10 Gbit/s, ten times as fast as Gigabit Ethernet. The first 10 Gigabit Ethernet standard, IEEE Std 802.3ae-2002, was published in 2002. Subsequent standards encompass media types for single-mode fiber (long haul), multi-mode fiber (up to 400 m), copper backplane (up to 1 m) and copper twisted pair (up to 100 m). All 10-gigabit standards were consolidated into IEEE Std 802.3-2008. Most 10-gigabit variants use 64b/66b PCS code (-R). 10 Gigabit Ethernet, specifically 10GBASE-LR and 10GBASE-ER, enjoys significant market shares in carrier networks.

25 Gbit/s

Single-lane 25-gigabit Ethernet is based on one 25.78125 GBd lane of the four from the 100 Gigabit Ethernet standard developed by the P802.3by task force. 25GBASE-T over twisted pair was approved alongside 40GBASE-T within IEEE 802.3bq.

40 Gbit/s

This class of Ethernet was standardized in June 2010 as IEEE 802.3ba. The work also included the first 100 Gbit/s generation, published in March 2011 as IEEE 802.3bg. A 40 Gbit/s twisted-pair standard was published in 2016 as IEEE 802.3bq-2016.

50 Gbit/s

The IEEE 802.3cd task force developed 50 Gbit/s along with next-generation 100 and 200 Gbit/s standards using 50 Gbit/s lanes.

100 Gbit/s

The first generation of 100 Gigabit Ethernet using 10 and 25 Gbit/s lanes was standardized in June 2010 as IEEE 802.3ba alongside 40 Gigabit Ethernet. The second generation using 50 Gbit/s lanes was developed by the IEEE 802.3cd task force along with 50 and 200 Gbit/s standards. The third generation using a single 100 Gbit/s lane was standardized in September 2022 as IEEE 802.3ck along with 200 and 400 Gbit/s Ethernet.

200 Gbit/s

First generation 200 Gbit/s have been defined by the IEEE 802.3bs task force and standardized in 802.3bs-2017. The IEEE 802.3cd task force has developed 50 and next-generation 100 and 200 Gbit/s standards using one, two, or four 50 Gbit/s lanes respectively. The next generation using 100 Gbit/s lanes was standardized in September 2022 as IEEE 802.3ck along with 100 and 400 Gbit/s PHYs and attachment unit interfaces (AUI) using 100 Gbit/s lanes.

400 Gbit/s

An Ethernet standard capable of 200 and 400 Gbit/s is defined in IEEE 802.3bs-2017. 1 Tbit/s may be a further goal. In May 2018, IEEE 802.3 started the 802.3ck task force to develop standards for 100, 200, and 400 Gbit/s PHYs and attachment unit interfaces (AUI) using 100 Gbit/s lanes. The new standards were approved in September 2022. In 2008, Robert Metcalfe, one of the co-inventors of Ethernet, said he believed commercial applications using Terabit Ethernet may occur by 2015, though it might require new Ethernet standards. It was predicted this would be followed rapidly by a scaling to 100 Terabit, possibly as early as 2020. These were theoretical predictions of technological ability, rather than estimates of when such speeds would actually become available at a practical price point.

800 Gbit/s

The Ethernet Technology Consortium proposed an 800 Gbit/s Ethernet PCS variant based on tightly bundled 400GBASE-R in April 2020. In February 2024, the IEEE 802.3df Task Force defined variants for 800 Gbit/s Ethernet over twinaxial copper, electrical backplanes, single-mode and multi-mode optical fiber along with new 200 and 400 Gbit/s variants using 100 Gbit/s lanes.

1.6 Tbit/s

In December 2022, IEEE started the P802.3dj Task Force to define variants for 200, 400, 800 and 1600 Gbit/s over twinaxial copper, electrical backplanes, single-mode and multi-mode optical fiber along with new variants using 100 and 200 Gbit/s lanes.

First mile

Ethernet in the first mile provides Internet access service directly from providers to homes and small businesses.

Sublayers

Starting with Fast Ethernet, the physical layer specifications are divided into three sublayers in order to simplify design and interoperability:

Twisted-pair cable

Several varieties of Ethernet were specifically designed to run over 4-pair copper structured cabling already installed in many locations. In a departure from both 10BASE-T and 100BASE-TX, 1000BASE-T and above use all four cable pairs for simultaneous transmission in both directions through the use of echo cancellation. Using point-to-point copper cabling provides the opportunity to deliver electrical power along with the data. This is called power over Ethernet and there are several variations defined in IEEE 802.3 standards. Combining 10BASE-T (or 100BASE-TX) with Mode A allows a hub or a switch to transmit both power and data over only two pairs. This was designed to leave the other two pairs free for analog telephone signals. The pins used in Mode B supply power over the spare pairs not used by 10BASE-T and 100BASE-TX. 4PPoE defined in IEEE 802.3bt can use all four pairs to supply up to 100 W. The cable requirements depend on the transmission speed and the employed encoding method. Generally, faster speeds require both higher-grade cables and more sophisticated encoding.

Minimum cable lengths

Some fiber connections have minimum cable lengths due to maximum level constraints on received signals. Fiber ports designed for long-haul wavelengths may require a signal attenuator if used within a building. 10BASE2 installations, running on RG-58 coaxial cable, require a minimum of 0.5 m between stations tapped into the network cable to minimize reflections. 10BASE-T, 100BASE-T, and 1000BASE-T installations running on twisted pair cable use a star topology. No minimum cable length is required for these networks.

Related standards

Some networking standards are not part of the IEEE 802.3 Ethernet standard, but support the Ethernet frame format, and are capable of interoperating with it. Other networking standards do not use the Ethernet frame format but can still be connected to Ethernet using MAC-based bridging. Other special-purpose physical layers include Avionics Full-Duplex Switched Ethernet and TTEthernet.

This article is derived from Wikipedia and licensed under CC BY-SA 4.0. View the original article.

Wikipedia® is a registered trademark of the Wikimedia Foundation, Inc.
Bliptext is not affiliated with or endorsed by Wikipedia or the Wikimedia Foundation.

View original